AMC2100 Series Electromagnetic Flowmeter

AMC2100 Series Electromagnetic Flowmeter
ALIAMAG AMC2100 Series, Converter For Electromagnetic Flowmeter Model AMC2100 Series.

ALIA GROUP INC.

PT. Totalitas Teknik Indonesia is the Indonesian Authorized Distributor of AMC2100 Products Series from ALIA GROUP INC.

HOTLINE: +62 812-3340-4116
AMC2100 Series Electromagnetic Flowmeter

Description Product of AMC2100 Series

AMC2100 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors.
The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.

Feature Product of AMC2100 Series

- Three line LCD display Flow Rate / Totalizer
- Accuracy of +/-0.4% value of reading
- Bi-directional flow measurement, current and pulse output
- Large digital display
- MODBUS / HART communication

Specification Product of AMC2100 Series

Excitation DC pulsed
Display 3 Lines LCD with illumination

Line 1:
11 Digit totalizer for forward flow
11 Digit totalizer for reverse flow
11 Digit totalizer for difference

Line 2:
5 Digit flowrate / velocity / % / mA / Hz

Line 3:
Parameter / Query / Clr tot / Query LOG / Alarm, Guidance

Totalizer Unit:
t, kg, g, lb, Ston, Lton, m3, L, mL, Igal, gal, Mgal, bbl, ft3, a-ft

Time Unit:
sec, min, hour, day
Measuring Range Min. 0-0.15 m/s Max. 0-15 m/s
Accuracy +/-0.4% of reading (Velocity≥0.5 m/s)
+/-0.002 m/s (Velocity<0.5 m/s)
Repeatability +/-0.1% of reading
Current Output 4-20 mA (Isolated) Load: Max. 600 Ω
Pulse Output Open collector Rating: 3-30 VDC, 20 mA Max.
Pulse Rate 1) Scaled pulse (mL/Pulse, L/Pulse, Other)
2) Frequency: 0-5000 Hz
Pulse Width 50% of band width
Alarm High / Low with open collector output
Rating: 3-30 VDC, 20 mA Max.
Communication RS485 (MODBUS Protocol)
HART signal (Compatible)
Keypad 3 External keys for programming and display control
Data Storage Operation parameters and totalizer figures are stored by EEPROM for more than 10 years
Low Flow Cut-off 0-9.9%
Damping 0-99 Seconds
Density Setting 0.1-9.99 g/cm3
Self Diagnosis The following error messages are displayed if failure occurs
- Coil failure
- Power failure
- Overranged output
- Internal error
- Overflow
- Empty pipe
Cable Entry Standard: M20
Option: 1/2" NPTF
Protection Class IP65
Ambient Temperature -25-65 oC
Material Aluminium Alloy
Power Supply 90-260 VAC, 50/60 Hz
24 VDC +/-10% (Option)
Power Consumption 3-17 W (Dependent on sensor size)
Weight 1.4 kg
Mounting Wall mounting
Bracket on 2" pipe